Sudden Cardiac Arrest (SCA) is a leading cause of death globally. Response time is critical for survival. The HeartSine samaritan® PAD 300P was designed especially for use in public areas by providing a sophisticated defibrillator for adult or pediatric use, inside a lightweight and easy-to-operate system. Its advanced technology is balanced against the demands of real world use.
The 300P uses HeartSine’s practical Pad-Pak™, which incorporates the battery and electrodes in a single-use cartridge – meaning only one expiration date to monitor and only one item to replace after use. The 300P is suitable for use on adults and children. For children younger than 8 years or weighing less than 25 kg (55 lbs), a Pediatric-Pak™ is available.
How It Works
The HeartSine samaritan PAD is an automated external defibrillator (AED) that analyzes the heart rhythm and delivers an electrical shock to victims of Sudden Cardiac Arrest in order to restore the heart to normal rhythm. This user-friendly AED provides easy to follow visual and audio prompts to guide the rescuer from pad application to shock delivery, if required.
It’s lifesaving, pure and simple
Pediatric-Pak, pink in color, for use on patients younger than eight years of age weighing less than 25 kg/55 lbs.
Specifications:
Physical (With Pad-Pak™ Inserted)
Size: 20 cm x 18.4 cm x 4.8 cm (8.0 in x 7.25 in x 1.9 in)
Weight (including Pad-Pak Battery): 1.1 kg (2.4 lbs )
Defibrillator
Waveform: Self-Compensating Output Pulse Envelope (SCOPE) Biphasic waveform. Optimized biphasic escalating waveform compensates energy, slope and envelope for patient impedance.
Energy Selection
Adult: Shock 1: 150J; Shock 2: 150J; Shock 3: 200J
Pediatric: Shock 1: 50J; Shock 2: 50J; Shock 3: 50J
Pad-Pak — Electrode and Battery Cartridge
Shelf Life: Four years from manufacture date
Weight: 0.2 kg (0.44 lbs)
Size: 10 cm x 13.3 cm x 2.4 cm (3.93 in x 5.24 in x .94 in)
Battery Type: Lithium Manganese Dioxide (LiMnO2)
Capacity: > 60 shocks at 200J18V, 1.5 Amp Hrs
Electrodes: HeartSine samaritan® disposable defibrillation pads are supplied as standard with each device
Placement: Anterior-lateral (Adult); Anterior-posterior (Pediatric)
Active Gel Area: 100 cm2 (15.5 in2)
Cable Length: 1 meter (3.5 feet)
Defibrillation is a procedure used to treat life threatening conditions that affect the rhythm of the heart such as cardiac arrhythmia, ventricular fibrillation and pulseless ventricular tachycardia
Apparatus used to control heart fibrillation by application of an electric current to the chest wall or heart. An automated external defibrillator (AED) is a portable device that checks the heart ... AEDs are used to treat sudden cardiac arrest